Home >Module>LoRa>ASR6601
Operating band CN470 to 510MHZ,supporting CLASS -A/CLASS-C node type

[IC]:ASR6601

[Frequency]:CN470~510MHZ

[Power]:22dBm

[Distance]:5.6km

[Size]:14*20mm

[Introduction]:The E78-470LN22S(6601) series is a standard LoraWan node module designed and produced by Chengdu EBYTE Electronic Technology Co., Ltd., with operating band CN470 to 510MHZ,supporting CLASS -A/CLASS-C node type that supports both ABP/OTAA access, while the module features a variety of low-power modes, with a standard UARTfor external communicationinterfaces and AT for users The instructions are simply configured to access the standard LoraWan In the network, it's a great choice for current IoT applications.

1
No. Pin Name Pin direction Pin use
1 GND - ground wire, connected to the power reference
2 VCC - Power supply, range 2.5V to 3.7V(ceramic filter capacitor is recommended externally)
3 SETB - Wake-up pins with low power
4 DIO1 Input/output NC(reserve pin)
5 BUSY Input/output NC(reserve pin)
6 I2C_SDA Input/output NC(reserve pin)
7 I2C_SCL Input/output NC(reserve pin)
8 UART_CTS Input/output NC(reserve pin)
9 UART_RTS Input/output NC(reserve pin)
10 GND - ground wire, connected to the power reference
11 ANT - Antenna interface, stamp hole(50 ohm characteristic impedance)
12 GND - ground wire, connected to the power reference
13 GND - ground wire, connected to the power reference
14 GND - ground wire, connected to the power reference
15 GND - ground wire, connected to the power reference
16 XRES Input The external reset pin
17 ADC_IN Input NC(reserve pin)
18 AUX Input/output NC(reserve pin)
19 SETA Input/output NC(reserve pin)
20 UART_RX Input/output UART RX pin
21 UART_TX Input/output UART TX pin
22 SWD_DATA Input/output SWD Data pin
23 SWD_CLK Input/output SWD Clock pin
24 GND - ground wire, connected to the power reference
25 SPI_MISO Input/output The SPI MISO test point, which is internally connected and cannot be used as an external SPI
26 SPI_NSS Input/output The SPI NSS test point, which is internally connected and cannot be used as an external SPI
27 SPI_MOSI Input/output The SPI MOSI test point, which is internally connected and cannot be used as an external SPI
28 SPI_SCK Input/output The SPI SCK test point, which is internally connected,cannot be used as an external SPI