Home >Modem>Signal interface conversion>Ethernet
NS4 Serial port to Ethernet module

[Interface signal]:Ethernet

[Interface mode]:UART serial port

[Size]:27*27*2.8mm

[Working voltage]:3.0~5.5V

[Introduction]:NS4 is an Ethernet serial server module that realizes serial data ⇌ Ethernet data conversion; it has a variety of Modbus gateway modes and TCP/DUP/MQTT/HTTP IoT gateway modes, which can meet the networking functions of various serial devices/PLCs. The module adopts LCC package, which is convenient for user equipment to be integrated on the PCB board.

PIN



No. Pin Functional Description
1GNDCommon ground terminal, power supply negative terminal input;
2NCdefault floating;
3NCdefault floating;
4NCdefault floating;
5NCdefault floating;
6NCdefault floating;
7GNDCommon ground terminal, power supply negative terminal input;
8GNDCommon ground terminal, power supply negative terminal input;
9GNDCommon ground terminal, power supply negative terminal input;
10GNDCommon ground terminal, power supply negative terminal input;
11NCdefault floating;
12NCdefault floating;
13NCdefault floating;
14NCdefault floating;
15TXD2The serial port sends data, only supports 3.3V TTL, if it is connected to 5V, level conversion is required;
16RXD2The serial port receives data, only supports 3.3V TTL, if it is connected to 5V, level conversion is required;
17NCdefault floating;
18NCdefault floating;
19GNDCommon ground terminal, power supply negative terminal input;
20GNDCommon ground terminal, power supply negative terminal input;
21VCCPositive power input, supports 3-5.5V input, can be used with pin 22 at the same time;
22VCCPositive power input, support 3-5.5V input; can be used with pin 21 at the same time;
23NCdefault floating;
24NCdefault floating;
25NCdefault floating;
26NCdefault floating;
27NCdefault floating;
28NCdefault floating;
29NCdefault floating;
30NCdefault floating;
31NCdefault floating;
32NCdefault floating;
33485EN-2Serial port 2 RS485 enable pin, normally low, pulled high when sending data
34NCdefault floating;
35NCdefault floating;
36485EN-1Serial port 1RS485 enable pin, normally low, pulled high when sending data
37NCdefault floating;
38NCdefault floating;
39NCdefault floating;
40NCdefault floating;
41SPDLEDNetwork port data indicator
42LINKLEDNetwork port connection indicator
43RX+Ethernet receives RX+ signal;
44RX-Ethernet receives RX-signal;
45TX+Ethernet sends TX+ signal;
46TX-Ethernet sends TX-signal;
47RESTOREReset pin, pull down for more than 5 seconds to take effect
48TXD1The serial port sends data, only supports 3.3V TTL, if it is connected to 5V, level conversion is required;
49RXD1The serial port receives data, only supports 3.3V TTL, if it is connected to 5V, level conversion is required;
50NCdefault floating;
51NCdefault floating;
52NCdefault floating;
533.3VCan output voltage 3.3V;
54GNDCommon ground terminal, power supply negative terminal input;
55NCdefault floating;
56NCdefault floating;
57NCdefault floating;
58NCdefault floating;
59NRSTModule reset, pull down for more than 1ms to take effect
60NETNetwork connection indicator, output 2S square wave if the connection is successful
If the connection is unsuccessful, output a 1S rectangular wave, pull it high for 0.9S, and pull it low for 0.1S
61NCdefault floating;
62NCdefault floating
63NCdefault floating;
64NCdefault floating;
65LINK1Serial port 1 data link indicator, UDP mode output low level;
In other modes, if the connection is successful, the output will be low level, and if there is no connection, the output will be high level;
66DATA1Serial port 1 data indicator pin, output 50ms square wave when there is data interaction;
67LINK2Serial port 2 data link indicator, UDP mode output low level;
In other modes, if the connection is successful, the output will be low level, and if there is no connection, the output will be high level;
68DATA2Serial port 2 data indicator pin, output 50ms square wave when there is data interaction;
69NCdefault floating;
70NCdefault floating;
71NCdefault floating;
72NCdefault floating;